307-3063 hydraulic fan motor For CAT 426F backhoe loader

Short Description:

350-0666/335-8197 hydraulic fan motor is heavy-duty variable axial piston hydraulic fan motor, aftermarket OEM replacement spare part for CAT 422E backhoe loader cooling hydraulic system.

Product Detail

Product Tags

description

307-3063 fan gear motor is the core actuator of cooling hydraulic circuit for CAT 426F backhoe loader. Driven by pressurized hydraulic oil supplied by matched fan pump, it converts hydraulic power into rotary power to drive cooling fan and dynamically adjust fan speed for stabilizing engine operating temperature. Internal gear pair, bearing and seal assembly adopt precision hobbing and surface hardening technology, maintaining stable torque output and low internal leakage under medium working pressure and frequent variable load. During long-time earthmoving and loading operation, the motor housing can withstand cyclic pressure impact and medium high oil temperature. The housing is made of high-strength cast iron with stress relief annealing treatment, featuring high rigidity and anti-deformation performance. All friction mating parts are precision processed to reduce abrasive wear caused by tiny solid particles in hydraulic oil. Each fan motor passes strict hydraulic bench inspection before shipment, including torque test, speed test, starting performance test, durability test, internal leakage test and noise detection, ensuring 1:1 interchangeability with OEM parts.

product parameters

Part No:307-3063
Type:Gear Type Hydraulic Fan Motor
Displacement:26 cc/rev
Applicable Equipment:CAT 426F Backhoe Loader, compatible with 415F,420F,427F,428F
Control Mode:Hydraulic pressure proportional control
Material:High-strength cast iron housing, alloy steel gear pair, roller bearing, FKM fluorine rubber sealing rings
Surface Treatment:Precision machining, surface hardening, anti-corrosion coating
Drive Method:Hydraulic oil drive
Nominal Working Pressure:23 MPa
Max Instantaneous Peak Pressure:29 MPa
Feature:OEM replacement fan motor, compact structure, low starting resistance, stable rotation, direct drop-in fit, matched with supporting fan pump for cooling system
Package:Independent anti-rust packing + Standard export wooden case
Storage suggestion:Keep dry, avoid moisture, rust and collision, indoor constant temperature storage, stay away from corrosive gas

advantage

・307-3063 gear hydraulic fan motor, OEM replacement, perfectly matched with supporting fan pump for CAT426F backhoe loader cooling system
307-3063 hydraulic fan motor is custom fitted for CAT426F backhoe loader cooling circuit. It converts hydraulic pressure into rotary torque to drive cooling fan. Stable torque output ensures fan can adjust speed flexibly under continuous earthmoving and loading operation, preventing engine overheating.
・Precision hardened alloy steel gear pair, stable torque output and low running noise
Alloy steel gear pair adopts precision hobbing and surface hardening process. It maintains steady torque output under variable inlet pressure. Volumetric efficiency stays high to guarantee consistent fan rotation for cooling circuit.
・Optimized internal flow channel structure and upgraded FKM sealing assembly, good anti-cavitation & medium temperature resistance
Optimized internal flow path reduces oil turbulence and cavitation risk. FKM seal set delivers outstanding medium-temperature and hydraulic oil aging resistance. It effectively prevents internal and external oil leakage, avoiding premature component wear caused by oil contamination, minimizing unexpected machine downtime.
・Compact lightweight design, convenient installation and maintenance to protect radiator and engine assembly
This 307-3063 fan motor adopts compact lightweight structure, easy for disassembly and maintenance. It provides stable rotary power for cooling fan. It maintains cooling hydraulic system operating normally, preventing radiator overheating caused by insufficient fan torque or unstable rotation, ideal replacement for overhaul and daily maintenance of CAT426F backhoe loader.

FAQ 

Q1: What machine models can 307-3063 fan motor fit?
A1: Mainly for CAT426F backhoe loader, also interchangeable for CAT415F,420F,427F,428F F-series backhoe loaders. Confirm part number before purchase.

Q2: What is the main advantage of gear type fan motor on F-series backhoe loader?
A2: Small footprint, simple structure and lower failure rate. It is well suited for medium-load digging, backfilling and road maintenance jobs.

Q3: What causes the fan to rotate intermittently after motor replacement?
A3: The common reason is air trapped in hydraulic circuit, or insufficient oil supply caused by blocked filter. Complete air bleeding and filter replacement can solve most of this issue.

Q4: How to check whether the gear pair inside this motor is worn?
A4: Check external leakage and monitor fan speed under load. If speed drops sharply under load without pressure change, internal gear wear is highly suspected.

Q5: What maintenance tips to extend service life of this gear fan motor?
A5: Keep hydraulic oil clean, avoid long-time overpressure operation. Inspect seal leakage and abnormal noise every 1000 working hours.

warehouse

We have built four spare parts warehouses in Xuzhou, Jining, Kunshan and Changsha to provide customers from all over the world with a variety of high-quality spare parts. We can basically ship self-provided spare parts within three days after confirming the order. If the spare parts need to be adjusted or processed, they will be shipped within 7-30 days.